Discussion:
[N8VEM: 19755] Grant Searle's multicomputer revisited; bugfix
RHKoolaap
2015-06-28 14:49:01 UTC
Permalink
H all,

when 'reset' (or 'monitor' in BASIC) is typed, the ROM gets paged back in
and control is passed to the monitor, however this did not reset the MMU.
After running CP/M-3, memory page 1 remained active, giving problems trying
to start CP/M-3 again. (the loader assumes to start in page 0)
This has been fixed with a monitor ROM update which can be downloaded here:
http://www.filedropper.com/filemanager/public.php?service=files&t=dddf53564ed3f4ecef6f0b9ad293e6c1

simply replace the CMON21.HEX with the one in your FPGA directory and
rebuild.


success RHK
--
You received this message because you are subscribed to the Google Groups "N8VEM" group.
To unsubscribe from this group and stop receiving emails from it, send an email to n8vem+***@googlegroups.com.
To post to this group, send email to ***@googlegroups.com.
Visit this group at http://groups.google.com/group/n8vem.
For more options, visit https://groups.google.com/d/optout.